| Plugin ID | 67 |
| Plugin name | APC SmartSlot factory account |
| Plugin filename | APC SmartSlot factory account.plugin |
| Plugin filesize | 2949 bytes |
| Plugin family | Backdoors |
| Plugin created name | Marc Ruef |
| Plugin created email | marc dot ruef at computec dot ch |
| Plugin created web | http://www.computec.ch |
| Plugin created company | computec.ch |
| Plugin created date | 2004/02/20 |
| Plugin updated name | Marc Ruef |
| Plugin updated email | marc dot ruef at computec dot ch |
| Plugin updated web | http://www.computec.ch |
| Plugin updated company | computec.ch |
| Plugin updated date | 2004/11/13 |
| Plugin version | 1.5 |
| Plugin changelog | Corrected the plugin structure and added the accuracy values in 1.5 |
| Plugin protocol | tcp |
| Plugin port | 23 |
| Plugin procedure detection | open|send apctest\n|sleep|send TENmanUFactOryPOWER\n|sleep|close|pattern_exists Factory Menu OR Final Functional Test |
| Plugin detection accuracy | 90 |
| Plugin comment | This plugin was written with the ATK Attack Editor. |
| Bug advisory | http://www.securityfocus.com/archive/1/ |
| Bug produced name | AOC |
| Bug produced email | info at apcc dot com |
| Bug produced web | http://www.apcc.com |
| Bug affected | APC 9606 SmartSlot |
| Bug not affected | Other solutions |
| Bug vulnerability class | Weak Authentication |
| Bug description | The remote APC device can be accessed by telnet with any username and the factory default password TENmanUFactOryPOWER. |
| Bug solution | Disable the telnet service or prevent unwanted access to the port with firewalling. |
| Bug fixing time | 10 minutes |
| Bug exploit availability | Yes |
| Bug exploit url | http://www.securityfocus.com/bid/9681/exploit/ |
| Bug remote | Yes |
| Bug local | Yes |
| Bug severity | High |
| Bug popularity | 3 |
| Bug simplicity | 7 |
| Bug impact | 9 |
| Bug risk | 6 |
| Bug Nessus risk | High |
| Bug check tools | Nessus is able to check in a similar way as like this plugin can do. |
| Source SecurityFocus BID | 9681 |
| Source Nessus ID | 12066 |
| Source Literature | Hacking Exposed: Network Security Secrets & Solutions, Stuart McClure, Joel Scambray and George Kurtz, February 25, 2003, 4th Edition, McGraw-Hill Osborne Media, ISBN 0072227427 |
| Source Misc. | http://www.networkscanning.com/APC-SmartSlot-factory-account-VSS_12066.html |